beech road - internal wall insulation
The client had visited our show house which made them realise that refitting their kitchen was an opportunity to radically improve the thermal performance.
Internal wall insulation was used to avoid altering the appearance of the back of the house.
Existing plaster stripped back to brickwork
140mm UdiInReco woodfibre insulation boards mechanically fixed to walls, following window reveal installation; giving a U value of 0.35w/m2.k
Proclima Contega Solido airtightness tape around window frame, prior to insulation board fixing
Walls plastered with UdiMultigrund vapour control base coat, finished with Baumit Klima Glatte.
Retrofit component: internal wall insulation
Further information is available in the Retrofit Pattern Book