arley drive - ground floor insulation

floor boards and joists removed throughout ground floor

ground floor rewiring ran throughout through protective cable housing

cleared front reception, with steel bar inserted into ground to assist in insulation depth

front reception technopor insulation installation commences

approximately 400mm of technopor insulation installed

rear reception filled with technopor prior to tamping

technopor rough level

floor laser level checked post tamping

cemwood layer acts as binding

front reception cemwood tamped and levelled

protective sheeting prevents insulation disturbance

commencing intello air tight and vapour control membrane installation

intello installed in rear dining room with airtightness tape

front reception with airtightness taped intello membrane

Udistep high density wood fibre underlay board (8mm) installation commenced

front reception Udistep installation completed

Dining room Udistep installation completed, prior to lithotherm underfloor heating system installation

Completed Lithotherm install, prior to engineered floorboards being laid