arley drive - ground floor insulation
floor boards and joists removed throughout ground floor
ground floor rewiring ran throughout through protective cable housing
cleared front reception, with steel bar inserted into ground to assist in insulation depth
front reception technopor insulation installation commences
approximately 400mm of technopor insulation installed
rear reception filled with technopor prior to tamping
technopor rough level
floor laser level checked post tamping
cemwood layer acts as binding
front reception cemwood tamped and levelled
protective sheeting prevents insulation disturbance
commencing intello air tight and vapour control membrane installation
intello installed in rear dining room with airtightness tape
front reception with airtightness taped intello membrane
Udistep high density wood fibre underlay board (8mm) installation commenced
front reception Udistep installation completed
Dining room Udistep installation completed, prior to lithotherm underfloor heating system installation
Completed Lithotherm install, prior to engineered floorboards being laid